It is a technologically advanced
that allows making careful adjustments
pH or ORP in industrial applications.
SIMPLE SET
Thanks to the functional microswitches is simple
configure and it is not necessary to go into programming.
EASY TO MEASURE
The calibration has never been easier: the tool able
recognize the buffer solutions, automatically making
calibration, suspending the dosage and indicating
the state of efficiency of the electrode.
UNIVERSAL FOOD
The instrument can be fed with the same tension
between 22 and 265 Vac.
DEGREE OF PROTECTION IP 65
Series PR-75 is protected by the box polopropileno,
that protects the electronics, wiring and even
The BNC to connect the electrode.
electrical isolation OUT OF 4 ... 20 mA
The ideal solution to connect with a VCR or
with a data acquisition system, without any interference.
Technical Data:
PR75 Model-T (Timed):
DIMENSIONS: 144 * 144 * 103 mm.
PLAN FOR FIXING: 136 * 136 mm +2 mm. max.
INTERNAL MEASURES: 90 mm.
DEGREE OF PROTECTION: IP65.
SECTION of the terminals: 4mm2, or 2.4 mm diameter.
FOOD: Universal 22 ... 265V 50-60 Hz.
CONSUMPTION: 3W.
SET POINTS: 2 configurable relays.
MAXIMUM LOAD ON RELAY: 3A 250VAC.
OUT IN FREQUENCY: OPEN-COLLECTOR-80V MAX 50mA.
TEMPERATURE OF WORK: 0 ... 50 ° C.
Storage temperature: -10 ... +70 ° C.
SCALE OF MEASURE OF pH: 0 ... 14,00 / 0 ... 14.0.
ACCURACY OF ACTION: ± 0.01 pH.
SCALE OF MEASURE redox -999 ... +999 mV.
ACCURACY OF ACTION: ± 1 mV.
Input impedance:> 1013 ohm.
SPEED OF ACQUISITION: 3 seconds.
CAL OFFSET pH: -2 ... +2 pH.
CAL GAIN pH: -5 ... +20%.
CALIBRATION redox ± 150 mV.
TEMPERATURE COMPENSATION MANUAL / AUTO 0 ... 125 ° C.
SETTING THE SET POINT: ON / OFF - Timed.
Hysteresis THE SET POINT: 0.1 pH / 10 mV.
TRANSMITTED OUTPUT: 4 ... 20 mA, resolution 200 points, 400 ohm load.
Model PR75 P (Proportional):
DIMENSIONS: 144 * 144 * 103 mm.
PLAN FOR FIXING: 136 * 136 mm +2 mm. max.
INTERNAL MEASURES: 90 mm.
DEGREE OF PROTECTION: IP65.
SECTION of the terminals: 4mm2, or 2.4 mm diameter.
FOOD: Universal 22 ... 265V 50-60 Hz.
CONSUMPTION: 3W.
SET POINTS: 2 configurable relays.
MAXIMUM LOAD ON RELAY: 3A 250VAC.
OUT IN FREQUENCY: OPEN-COLLECTOR-80V MAX 50mA.
TEMPERATURE OF WORK: 0 ... 50 ° C.
Storage temperature: -10 ... +70 ° C.
SCALE OF MEASURE OF pH: 0 ... 14,00 / 0 ... 14.0.
ACCURACY OF ACTION: ± 0.01 pH.
SCALE OF MEASURE redox -999 ... +999 mV.
ACCURACY OF ACTION: ± 1 mV.
Input impedance:> 1013 ohm.
SPEED OF ACQUISITION: 3 seconds.
CAL OFFSET pH: -2 ... +2 pH.
CAL GAIN pH: -5 ... +20%.
CALIBRATION redox ± 150 mV.
TEMPERATURE COMPENSATION MANUAL / AUTO 0 ... 125 ° C.
SETTING THE SET POINT: ON / OFF - IN CURRENT PROPORTIONAL.
Hysteresis THE SET POINT: 0.1 pH / 10 mV.
TRANSMITTED OUTPUT: 4 ... 20 mA, resolution 200 points, 400 ohm load.
| Model |
|
| PR75A |
wall |
| |
144x144x90 |
| PR75B |
panel |
| |
144x144x90 |
| PR75C |
panel |
| |
96x96x95 |
| Available Options: |
| Modelo: |
|
|