To measure and control pH, Chlorine Free, conductivity and temperature.
Includes:
Instruments and PC95-CD75.
Sonda-amperometric Chlorine Free (Pt-Cu).
Probes-pH and conductivity.
Self-Performance and sensors (pH, conductivity and Chlorine Free).
Filter-water inlet valve and for Self.
Complete installation kit included.
KONTROL Panel Series Features:
- Self for all measures.
- Sensor with Portasondas flow regulating valve and flow control.
- Alarm signal for lack of flow.
- Instrument with IP65 degree of protection.
- 2 relays Connection (5A - 250 Va).
- Departures 4 .. 20 mA for each of the measured parameters, the possibility of imposing the range.
- Food: 230 Vac (standard) or 155 Vac (upon request).
- Set point and configurable alarms.
- Bombs in pause mode during calibration.
- Measure and temperature compensation with PT100 probe.
- Compensation of the extent of chlorine on the pH.
Technical Data:
Instrument PC95:
ACTION: 240 mm - 245 mm - 140 mm.
INDEX OF PROTECTION: IP65.
SECTION of the terminals: 4mm2, or 2.4 mm diameter.
FOOD: Standard 230V 50-60 Hz.
CONSUMPTION: 15W.
Relays CONTROL: 2 (Free Chlorine and pH).
MAXIMUM CAPACITY IN RELAY: 3A 250VAC (with resistive load).
TEMPERATURE OF WORK: 0 ... 50 ° C.
Storage temperature -10 ... +70 ° C.
SCALE OF MEASURE OF pH: pH 0 ... 14.00.
ACCURACY: 0.01 pH unit.
Input impedance:> 1013 ohm.
COMPENSATION IN TEMPERATURE: Manual / Automatic 0 ... 125 ° C.
3 TYPES OF SCHEDULE SET POINT: On / Off - Proportional - Beats.
Analog Outputs: 0 / 4 ... 20 mA for each parameter. Resolution 255 points. 1 K ohm maximum load.
SCALE OF MEASURE Cl: 0 ... 5.00 ppm or mg / l.
ACCURACY: 0.01 ppm.
COMPENSATION WITH PH: Valid until pH 8.30.
CAL PARAMETERS: Automatic.
FLOW SENSOR: Included.
Instrument CD75:
DIMENSIONS: 144 * 144 * 103 mm.
PLAN FOR FIXING: 136 mm * 136 + 2 mm max.
INTERNAL DIMENSIONS: 90 mm.
DEGREE OF PROTECTION: IP65 front IP20 rear.
SECTION OF CABLE: 4mm2, or 2.4 mm diameter.
FOOD: Universal 22 ... 265V 50-60 Hz.
CONSUMPTION: 3W.
SET POINTS: 2 Independent configurable relays.
MAXIMUM LOAD ON RELAY: 3A 250VAC.
TEMP WORK: 0 ... 50 ° C.
Storage temperature: -10 ... +70 ° C.
RANGES OF ACTION AND PRECISION: 2 ± 0.01 / 5 ± 0.01 / 20 ± 0.01 / 50 ± 0.1 / 200 ± 0.1 / 500 ± 0.3 / 1,000 ± 2 / 2.000 ± 2 / 5,000 ± 5 / 10,000 ± 200 / 20,000 ± 200.
CONSTANT FOR CELL: 0.1 / 0.2 / 1 cm -1.
CAL 0: ± 10% F.S.
CAL GAIN: ± 30%.
TEMPERATURE COMPENSATION: manual / automatic 0 ... 125 ° C.
REGULATION ON THE SET POINT: ON / OFF - TEMPORIZED.
Hysteresis ON THE SET: Programmable.
DELAY ON THE SET 2: 0 ... 99 minutes.
TRANSMITTED OUTPUT: 4 ... 20 mA, resolution 200 points, 400 ohm load.
|